checkCIF/PLATON report (publication check)

No syntax errors found.                               CIF dictionary
Please wait while processing .... Interpreting this report
Datablock: shelxl
Bond precision: C-C = 0.0084 A Wavelength=0.71070
Cell: a=9.9820(3) b=15.8940(5) c=14.1120(4)
alpha=90 beta=92.3710(13) gamma=90
Calculated Reported
Volume 2237.01(12) 2237.01(12)
Space group P 21/c P 21/c
Hall group -P 2ybc -P 2ybc
Moiety formula C22 H24 F8 N2 Pt C22 H24 F8 N2 Pt
Sum formula C22 H24 F8 N2 Pt C22 H24 F8 N2 Pt
Mr 663.51 663.52
Dx,g cm-3 1.970 1.970
Z 4 4
Mu (mm-1) 6.351 6.351
F000 1280.0 1280.0
F000' 1274.21
h,k,lmax 13,21,18 13,21,18
Nref 5594 5440
Tmin,Tmax 0.237,0.218 0.218,0.218
Tmin' 0.237
Correction method= 'MULTI-SCAN'
Data completeness= Ratio = 0.972 Theta(max)= 28.360
R(reflections)= 0.0426( 3667) wR2(reflections)= 0.0920( 5440)
S = 1.005 Npar= 304

The following ALERTS were generated. Each ALERT has the format
       test-name_ALERT_alert-type_alert-level.
Click on the hyperlinks for more details of the test.

Alert level B PLAT232_ALERT_2_B Hirshfeld Test Diff (M-X) Pt1 - C1 .. 11.74 su
Alert level C PLAT232_ALERT_2_C Hirshfeld Test Diff (M-X) Pt1 - C4 .. 8.27 su PLAT432_ALERT_2_C Short Inter X...Y Contact F7 .. C12 .. 2.94 Ang.
0 ALERT level A = In general: serious problem 1 ALERT level B = Potentially serious problem 2 ALERT level C = Check and explain 0 ALERT level G = General alerts; check 0 ALERT type 1 CIF construction/syntax error, inconsistent or missing data 3 ALERT type 2 Indicator that the structure model may be wrong or deficient 0 ALERT type 3 Indicator that the structure quality may be low 0 ALERT type 4 Improvement, methodology, query or suggestion 0 ALERT type 5 Informative message, check


Publication of your CIF

You should always attempt to resolve as many as possible of the alerts in all categories. Often the minor alerts point to easily fixed oversights, errors and omissions in your CIF or refinement strategy, so attention to these fine details can be worthwhile. In order to resolve some of the more serious problems it may be necessary to carry out additional measurements or structure refinements. However, the nature of your study may justify the reported deviations from the submission requirements of the journal and these should be commented upon in the discussion or experimental section of a paper - after all, they might represent an interesting feature.

If you wish to submit your CIF for publication in Acta Crystallographica Section C or E, you should upload your CIF via the web. If your CIF is to form part of a submission to another IUCr journal, you will be asked, either during electronic submission or by the Co-editor handling your paper, to upload your CIF via our web site.


PLATON version of 09/07/2006; check.def file version of 27/06/2006
Datablock shelxl - ellipsoid plot

Download CIF editor (enCIFer) from the CCDC
Test a new CIF entry